Bimba IntelliSens Manual do Utilizador Página 26

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 68
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 25
IntelliSense
®
Manual
26
Editing SIM Conguration
Figure 14: Cylinder Cong button
Any SIM in the main list can be congured by selecting the “Cong” button to the right of the SIM entry on the status
screen. The following conguration page will show. Click the button marked Retrieve Current Settings to bring all of
the current parameter values from the SIM memory into the web browser, including the SIM version, set-up and com-
munication parameters.
To save any changed values to the SIM memory, click the button Save Settings to SIM.
Figure 15: Save and retrieve Settings to and from the SIM
Basic SIM Settings
IntelliSense
®
Modes
IntelliSense
®
can be set up to monitor cylinders or pressure. In Cylinder Monitoring mode, IntelliSense
®
will monitor
cylinder performance, including stroke time and leakage, and allow alarms to be set. These alarms are triggered when
the set thresholds are crossed. In Pressure Monitoring mode, IntelliSense
®
will measure pressure and temperature
and alert you when the set-points are reached or crossed. The mode can be set by selecting the appropriate option
Vista de página 25